Good work!
Bill,
Glad to hear you found the problem. That is such a strange issue to actually notice, but now you are assured your system works as it should, when it is needed. So nice to have the "parts"...
|
Forum: Messages
01-02-18, 02:30 PM
|
Replies: 12
Views: 10,788
Sorry for the delay
Bill,
Somehow, you are creating a ground with your lead tester, and if that diode is bad, it could be closing the solenoid. I am having a difficult time though now that you tell me yours was wired...
|
Forum: Messages
12-23-17, 10:56 AM
|
Replies: 12
Views: 10,788
More...
Bill,
Yes, if you move the generator fuse wire to the downstream side of the master solenoid, it will impact the standby/run system, as it will no longer be connected directly to the battery. For...
|
Forum: Messages
12-23-17, 10:47 AM
|
Replies: 12
Views: 10,788
looking at wiring diagram...
Bill,
Here is a snap shot of your wiring diagram. Is this how it was wired before - or does this reflect how you have moved the generator wire now to the other side? The four posts on the older...
|
Forum: Messages
12-21-17, 10:28 AM
|
Replies: 12
Views: 10,788
No Picture required
Hi Bill,
Since you already disconnected the wires - no need for the picture. I will go to the hangar tomorrow and take a picture of mine - so that we can compare. I will look at wiring diagram...
|
Forum: Messages
12-20-17, 09:01 AM
|
Replies: 12
Views: 10,788
Wierd
Bill,
I will have to look at the wiring diagrams tonight and respond. What is your S/N? I have not heard this before, but to be honest, I always connect right up to the battery. Basically, that...
|