landing gear

I had similar problem on my 1975 P337G a few years back. The gear up position limit switch needed adjustment on my plane. BTW, if it is the same as my plane, the circuit breaker is a pull out type. If it occurs again, pull the limit switch out and a few seconds later push it back in. This should give green light with landing gear tucked away and stop the hydraulic pump from continous running.