Strainer reinstallation
When reinstalling the fuel strainer be sure not to overtighten the link which goes between the plunger and the cable. The link must be able to pivot at the top of the plunger. If it cannot, the cable will put a side load on the plunger when operated and will cause premature failure of the top O-ring.