why the combustion htr on a push-pull?
Sorry, but I just don't understand the thinking by Cessna engineers, nor why no one has made a modification through field approval or STC to remedy it.
The reason a combustion heater is necessary on most twins is simple - the engines are out hanging under the wings, so very inefficient to try and pipe that excess heat through an exhanger into the cabin. Our engines are not out under the wings- we have one right in front of us - just a like a single engine design. On single engine airplances it is a simple process to set-up a heat exchanger type system, no extra fuel or flame needed, to get heat into the cabin. You still have to have proper carbon monoxide detectors and sound exhaust system checks done under any system. Why not just heat the Skymaster the way a single engine plane does it? Has anyone ever tried to use a mod that gets nice engine heat into the cabin and eliminates the combustion heater? ________ Washington Dispensaries Last edited by rmorris : 03-12-11 at 12:00 PM. |
|
#2
|
||||
|
||||
|
The normal aspirated Skymaster has the heat exchanger feature. Only the Turbo and the P models use the combustion heater.
__________________
Herb R Harney 1968 337C Flying the same Skymaster for 49 years |
|
#3
|
|||
|
|||
|
turbo -v- aspirated
Quote:
Anyone out there ever tried to set up a turbo or p with heat exchanger type heat in lieu or in addition to the combustion model? ________ Puma Last edited by rmorris : 03-12-11 at 12:00 PM. |
|
#4
|
|||
|
|||
|
Quote:
|
|
#5
|
|||
|
|||
|
The T337H has a heat exchanger and only uses the heat from 2 cylinders. I guess it works good because the pilots don't whine about being cold.
Kim |
|
#6
|
|||
|
|||
|
I replaced the heater in my T337B two years ago with an O/H'd one from Janitrol ("Kelly Aerospace" now) and it was just under $2K through Harold Haskins (Dothan, AL). It was a totally new core and parts so while it was an "overhauled" heater it really is new now. I pulled the old one out and put the new one in and then my A&P's finished up one dififcult part of the process that was giving me some trouble and signed it off (less than $200). I spent half a day getting it out and half a day getting the new one back in. For certain steps of the in and out process it was really a 2-man job, and I had a good friend help for a couple of hours.
I can't get too excited over that endlessly quoted line "why light a fire" in the airplane for heating stuff. The heater works fine, it does the job, and if the other type had worked well at the time they designed the T's and P's I suspect they'd have used that instead. My A/C is certificated to 33K feet, and it needs a good heater when you get high and cold. Last edited by Paul Sharp : 02-17-09 at 10:14 PM. |
|
#7
|
|||
|
|||
|
heat exchange
Quote:
You suppose there is a way to convert to the 337H set-up and eliminate the Janitrol heater? ________ NASH 600 SPECIFICATIONS Last edited by rmorris : 03-12-11 at 12:02 PM. |
|
#8
|
|||
|
|||
|
The cost of a T337H Fwd exhaust system is 4K-5K then you have the ducting and control valves It will be much more cost effective to buy a new heater or two. The biggest problem with a Janitrol heater was getting a cracked combustion chamber and everyone expiring from CO posioning. But a heater/muffler type system will do the same thing.
Kim |
|
#9
|
|||
|
|||
|
Janitrol heater
Can the Janitrol heater be removed on a P model? We operate 100% of the time in the Caribbean, Mexico and Ceentral America. Never have a problem being too cold.
I would like to permanently remove the Janitrol and get rid of some of the space consuming plumbing. However, we want to do it correctly and legally. Are there any options?
__________________
Rick Gardner www.caribbeanskytours.com |
![]() |