Register | FAQ | Members List | Calendar | Search | Today's Posts | Mark Forums Read |
![]() |
|
Thread Tools | Rate Thread | Display Modes |
|
#1
|
||||
|
||||
Are the gear doors sagging overnight, partially open? The pump is running because there is a switch that is open. If you have to open the doors then let the pump close them it sounds like it may be a position issue. Any symptoms that could have caused this to start happening? Recent annual inspection or any adjustments made?
__________________
Herb R Harney 1968 337C Flying the same Skymaster for 47 years |
#2
|
|||
|
|||
powerpack
Have not done the annual or changed any thing and no the doors are not sagging at least not noticeable. Thanks for taking the time to help
|
#3
|
||||
|
||||
Power PAC
I had same type problem a number years ago. When gear retracted and gear doors closed power PAC kept running. Had to pull gear circuit breaker to reset it.
After trouble shoot it was found to be limit switch adjustment. Look there first. Jerry N34Ec |
#4
|
|||
|
|||
Powerpack
Thanks I am in the process of checking that. I will let you know what we find.
|
![]() |