Skymaster Forum  

Go Back   Skymaster Forum > Messages
Register FAQ Members List Calendar Today's Posts

Reply
Thread Tools Rate Thread Display Modes
  #1  
Unread 03-06-22, 08:37 PM
Joes Joes is offline
Registered User
 
Join Date: Dec 2021
Location: Abingdon, VA
Posts: 80
Joes is on a distinguished road
Inboard Tank fuel sending unit gasket replacement G model

I am in the middle of replacing the fuel sending units cork gaskets, how difficult is the removal and installation of the tubular capacitors in the inboard tank? Any help would be appreciated.
Reply With Quote
  #2  
Unread 03-07-22, 07:29 PM
hharney's Avatar
hharney hharney is offline
Forum Administrator
 
Join Date: Jul 2002
Location: Michigan (8D4)
Posts: 2,261
hharney is on a distinguished road
Are you referring to the main fuel inter-connects ? Rubber couplers?
__________________
Herb R Harney
1968 337C

Flying the same Skymaster for 47 years
Reply With Quote
  #3  
Unread 03-07-22, 07:45 PM
Joes Joes is offline
Registered User
 
Join Date: Dec 2021
Location: Abingdon, VA
Posts: 80
Joes is on a distinguished road
1973 G model type fuel quanity sending unit

Once you remove the bolts from the top of the tanks for the fuel sending units, two wires are attached to a tubular capacitor that sits upright in the tank and measures dielectric values in relationship to the fuel level. That was a mouthful, the tubes are upright in a cradle, just wondering how difficult were they to remove. Can't get the new gasket on without having them out of the tank. Thanks for responding.
Reply With Quote
  #4  
Unread 03-08-22, 12:47 AM
Dan schultz Dan schultz is offline
Registered User
 
Join Date: Nov 2018
Location: Ohio
Posts: 138
Dan schultz is on a distinguished road
They are installed in clips, pull the bottom of the capacitance tube forward towards the front engine and they will pop out of the clips. Make sure on reinstallation that they are oriented correctly, push back in the clips and they will snap in place.

N67S
Dan Schultz
Reply With Quote
  #5  
Unread 03-14-22, 05:37 AM
SkyMac's Avatar
SkyMac SkyMac is offline
Registered User
 
Join Date: Sep 2010
Location: Australia
Posts: 147
SkyMac is on a distinguished road
Hi Chaps

Apologies for the basic question, are the tubes marked with an up so that it can assist with installation or is it as simple as wires to the top.

Regards
Dave
__________________
Dave S
1974G
VH-DCS
Reply With Quote
  #6  
Unread 03-14-22, 07:40 AM
Joes Joes is offline
Registered User
 
Join Date: Dec 2021
Location: Abingdon, VA
Posts: 80
Joes is on a distinguished road
Capacitance Tube Orientation

The orientation of the tubes were with the white plastic insulator on the bottom.
Reply With Quote
  #7  
Unread 04-05-22, 06:30 PM
hayesjaj hayesjaj is offline
Registered User
 
Join Date: Apr 2019
Location: USA
Posts: 67
hayesjaj is on a distinguished road
I'm going to pull mine in the next week for a CIES update, I'll take pics if you still need them. They are very easy to remove and generally easy to put back in.
Reply With Quote
  #8  
Unread 04-05-22, 08:05 PM
Learjetter's Avatar
Learjetter Learjetter is offline
Registered User
 
Join Date: Jun 2010
Location: KOKC
Posts: 262
Learjetter is on a distinguished road
Quote:
Originally Posted by hayesjaj View Post
I'm going to pull mine in the next week for a CIES update, I'll take pics if you still need them. They are very easy to remove and generally easy to put back in.
Let me know how that CiES install goes. Mine was a bear and I have a blank spot between 35-50 gal per wing. Talked to CiES at AEA last week and think I can reorient my inboard sender to eliminate the irritating lack of fidelity between 35-50 gals.

‘77 NA G model with long range tanks (150 gal).
Reply With Quote
  #9  
Unread 04-05-22, 08:25 PM
hayesjaj hayesjaj is offline
Registered User
 
Join Date: Apr 2019
Location: USA
Posts: 67
hayesjaj is on a distinguished road
Quote:
Originally Posted by Learjetter View Post
Let me know how that CiES install goes. Mine was a bear and I have a blank spot between 35-50 gal per wing. Talked to CiES at AEA last week and think I can reorient my inboard sender to eliminate the irritating lack of fidelity between 35-50 gals.

‘77 NA G model with long range tanks (150 gal).
Will do! I’m doing my 73G and my brother is doing the family 69D so we will have a few good datapoints.
Reply With Quote
  #10  
Unread 04-05-22, 10:55 PM
wslade2 wslade2 is offline
Registered User
 
Join Date: Feb 2016
Location: none
Posts: 303
wslade2 is on a distinguished road
What is the orientation recommendation from cies?
Can sensors be installed without removing upper wing panels?
This is a near future project for me.
Reply With Quote
  #11  
Unread 04-05-22, 10:59 PM
hayesjaj hayesjaj is offline
Registered User
 
Join Date: Apr 2019
Location: USA
Posts: 67
hayesjaj is on a distinguished road
Quote:
Originally Posted by wslade2 View Post
What is the orientation recommendation from cies?
Can sensors be installed without removing upper wing panels?
This is a near future project for me.
For my 337G i’ll have to pull the wing panels since the access doors aren’t large enough to pass through the large flange. On pre 73 models (verified for 69) the resistive senders are smaller and can be pulled without removing the panels.

As for orientation, tbd.
Reply With Quote
  #12  
Unread 04-05-22, 11:23 PM
Learjetter's Avatar
Learjetter Learjetter is offline
Registered User
 
Join Date: Jun 2010
Location: KOKC
Posts: 262
Learjetter is on a distinguished road
On mine, I also pulled the wing panels. Not fun. Recommend supporting the booms and wing with jackstands. On my inboard tank, the forward access port (of three in the inboard tank) was the desired location for the sender. My tanks had baffles that precluded installing the CiES sender in the forward port….so I put them in the middle port, angled the float towards the fuel drains.

My problem is, my inboard sender tops out before fuel floats the outboard sender.

Im considering pulling the damn panels again, cut the baffle, and install the sender in the forward port to get more “up” float travel on the inboard sender so the outboard sender will float before the inboard sender hits the top of the tank.

Good luck with y’all’s installs!

Also…pro tip: power the CiES senders from ships power, not the gea24, and run both sets of sender signal wires to one gea24. Make sure you get gi275 software version 2.42 or 2.43.
Reply With Quote
Reply



Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is Off
HTML code is Off
Forum Jump


All times are GMT -4. The time now is 07:33 PM.


Powered by vBulletin® Version 3.6.9
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.