Electroluminescent subpanels

I've searched 'til I'm blue in the face but cannot find any reference to repairing electroluminescent subpanel lighting, although I am sure there is a thread somewhere. Anyone have suggestions where to get these panels repaired? I have a 1976 337G normal, SN33701743.
Reply With Quote
  #2  
Unread 11-16-02, 04:10 PM
Pete Somers Pete Somers is offline
Registered User
 
Join Date: Jul 2002
Location: Yorkshire. UK.
Posts: 229
Pete Somers is an unknown quantity at this point
Electroluminescent panel

Jim

The panels are not repairable if the are broken.
Make sure there is 115 volts AC across the black and the white wires from the back of the panel, if the volts are missing the inverter is more than likely u/s.

Peter
Reply With Quote
  #3  
Unread 11-17-02, 05:01 AM
skymstr02's Avatar
skymstr02 skymstr02 is offline
Ace of the Atmosphere
 
Join Date: Apr 2002
Location: Madison, MS
Posts: 329
skymstr02 is an unknown quantity at this point
Most of the problems that I've run across had the inverter defective. Its a black unit, mounted on the sidewall near the pilots left knee, and has th word "SCOTT" embossed on the outside. Its irregular shaped, with wires running out of it.
Reply With Quote
  #4  
Unread 11-17-02, 11:05 AM
Bob Cook Bob Cook is offline
N69S
 
Join Date: Apr 2002
Location: CYYZ,MYAT
Posts: 561
Bob Cook is an unknown quantity at this point
el panels

Jim

You did not tell us if all panels are dead or just one.

First of all check the voltage from the inverter and see if there is approximately 110 volts AC.

If voltage present then panels are shot. If there is no voltage disconnect panels and check voltage again. One panel may be drawing too much current.

There is a place in Witchita that will rebuild the panels (much brighter than before) or they will make all new panels for you.

You may want to consider putting a strip light along underneath the main panel overlay and illuminate that way.

The EL panels were a problem and probably less than 50% work now.


I will look up the name of the company if you are unable to get your running.

BTW I had same problem with my panels and had to replace the power supply. You can actually test the panels using house hold current.

FYI

Bob
Reply With Quote
  #5  
Unread 11-17-02, 06:38 PM
Jim Rainer's Avatar
Jim Rainer Jim Rainer is offline
Jim Rainer
 
Join Date: Apr 2002
Location: Memphis, TN
Posts: 163
Jim Rainer is an unknown quantity at this point
Thanks folks! I'll do some checking first. I just assumed the panels were at fault but it may be the power supply. I'm sure both panels are out. I like the idea of strip lighting even over the instrument panell itself.

Jim
Reply With Quote
Reply



Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is Off
HTML code is Off
Forum Jump


All times are GMT -4. The time now is 03:29 PM.


Powered by vBulletin® Version 3.6.9
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.