Unread 03-24-09, 05:05 PM
Pete Somers Pete Somers is offline
Registered User
 
Join Date: Jul 2002
Location: Yorkshire. UK.
Posts: 229
Pete Somers is an unknown quantity at this point
Ed
Thats good news, however if you certify a part as serviceable the unit should have been checked in accordance with with the manufactures spec and clearly it was not.
It has cost you money to go through the wiring, plugs and to find out it is the box you first started out suspecting.

Not good.

Regards
Pete
Reply With Quote
  #2  
Unread 03-24-09, 05:45 PM
Ernie Martin's Avatar
Ernie Martin Ernie Martin is offline
Administrator
 
Join Date: Apr 2002
Location: Miami, Florida
Posts: 989
Ernie Martin is an unknown quantity at this point
Pete, in theory I'm with you. But how many repair facilities have a shaker table to simulate vibration? For that matter, how many subject a repaired item to temperature limits to verify specifications? The issue here is going to be money. If Aero-Mach recognizes that it had an obligation to verify conformance across the spectrum of environmental conditions and fixes the unit without additional cost, I think Ed would be doing well.

Ernie
Reply With Quote
  #3  
Unread 03-24-09, 06:49 PM
edasmus edasmus is offline
Registered User
 
Join Date: Nov 2006
Location: ARR - Aurora, IL - USA
Posts: 420
edasmus is on a distinguished road
Send a message via AIM to edasmus
I hear what both of you are saying. I do struggle with this stuff all the time when it comes to maintenance bills. In a perfect world I would walk into the shop, tell of the problem, and they would fix it correctly the first time. Unfortunately it does not work that way all the time based on the experience I have had over 18+ years of airplane ownership and 7 years of Skymaster ownership. In the real world it becomes a process of elimination starting with the most likely cause and working from there. Inevitably something else gets broken in the process (which I just experienced with a fuel pump wire while trying to repair a leak in the pitot/static system). What I do look for in people is a good faith effort in trying to resolve the problem. Certainly I expect competence but not perfection. It becomes a balance between overall service and occasional frustrations, a balance between working with my home shop versus the time and expense of flying the plane around to different shops. My shop has been in the airplane business for 40+ years and my mechanic has been there since day one. They have been a Cessna repair station forever and I believe they have seen everything there is to see yet sometimes they still get fooled. I do pay for it, a lot, but looking at the big picture, they get most of it right. I wish I could do all this stuff myself but I can't, not even close. So as difficult as it can be, I have to put my faith and money in other people, encourage them to do their best, be a friend, not a jerk, and hope for the best. If I was truly dissatisfied, I would go somewhere else. As for Aero-Mach, they have been always polite on the phone and seem to be doing all they can to fix my signal conditioner. As for the cost, I will pay their bill knowing it was still less than getting a new one from Cessna and chalk it up as another chunk of money to owning an airplane. When the day comes that I don't want to pay anymore, I won't, and the airplane will be somewhere else. This forum is a great way to hopefully take a piece of that cost and put it back in our wallets (and use it for 100LL instead). It's all good!
Reply With Quote
  #4  
Unread 03-24-09, 08:17 PM
Ernie Martin's Avatar
Ernie Martin Ernie Martin is offline
Administrator
 
Join Date: Apr 2002
Location: Miami, Florida
Posts: 989
Ernie Martin is an unknown quantity at this point
Couldn't agree more. Great way to look at things.

Ernie
Reply With Quote
  #5  
Unread 03-24-09, 10:11 PM
stackj stackj is offline
Registered User
 
Join Date: Apr 2002
Location: Richmond, VA
Posts: 311
stackj is an unknown quantity at this point
Send a message via AIM to stackj
Absolutely a great attitude!
__________________
Jim Stack
Richmond, VA
Reply With Quote
  #6  
Unread 03-25-09, 05:31 PM
Roger's Avatar
Roger Roger is offline
Registered User
 
Join Date: Nov 2005
Location: FL-NY
Posts: 211
Roger is an unknown quantity at this point
I too have had reoccuring problems with my left fuel guage, and noticed something a few weeks ago when working on a fuel leak caused by a dried cork . If I played with the wires that go between the outboard sensor, and the inboard, it caused the fuel guage to spike, and at times work. This even if I isolated (taped down) the connections that went through the tank caps.

I now beleive that I may have a crack in the wire itself. Why else when I move them around while isolating the connections, should I get what amounts to different impendence or continuity .
Reply With Quote
  #7  
Unread 03-25-09, 06:00 PM
Pete Somers Pete Somers is offline
Registered User
 
Join Date: Jul 2002
Location: Yorkshire. UK.
Posts: 229
Pete Somers is an unknown quantity at this point
Roger
You have the resistor type system on your T337D, now this system requires quite a bit of maintenance, the grounding of the tank unit has to be 'spot on' if you have any corrosion under the tank units or the ground strap is not clean this system will not work correctly.
On the resistor type system a open circuit from the gauge to the the tank unit will cause full scale deflection of of the fuel gauge, and a short would cause the opposite effect.

Easy check for volts at the tank unit, also check that the tank unit is grounded and no corrosion on any of the connections.

Regards
Pete
Reply With Quote
Reply



Posting Rules
You may not post new threads