Skymaster Forum  

Go Back   Skymaster Forum > Messages
Register FAQ Members List Calendar Today's Posts

Reply
 
Thread Tools Rating: Thread Rating: 4 votes, 5.00 average. Display Modes
  #1  
Unread 01-01-09, 09:38 PM
JeffAxel JeffAxel is offline
Registered User
 
Join Date: Mar 2007
Location: Portland, Oregon
Posts: 150
JeffAxel is an unknown quantity at this point
Quote:
Originally Posted by rmorris View Post
Two questions:
1) Has anyone taken advantage of the C&D special show pricing and put in their heater replacement. If so, what was the cost of the heater, and what was the cost of the labor to swap it out. pirep on it?
2) IO've looked throughout my POH and can not seem to find the fuel flow requirement for the Janitrol heater on my T337C. I understand my new JPI fuel flow gauiges will not reflect the fuel used by the heater and I want to makie sure I'm calculating actual burn with the heater turned on...anyone have the fuel flow numbers?

-Robert Morris
rmorris@agsi.us
Robert,
the combustion heater uses 2.25lbs/hr on fuel, and draws it from the same tank as the front engine (left). As to the C&D heater, I swapped my old one out at the last annual. The new one actually works, the old one didn't. Be sure whoever does this for you actually reads the installation procedures and follows the checklist and checks that everything is set up properly, and then tests it at altitude. It seems that if the fuel pump for the heater is not up to spec, the heater won't light at altitude. Don't ask how I know! The folks who did this for me hadn't done this before, and didn't do it very well or very efficiently. The total cost was $6800. I won't be going back to this shop. The heater works well though, once it was set up properly.
Reply With Quote
  #2  
Unread 01-02-09, 06:37 AM
skymstr02's Avatar
skymstr02 skymstr02 is offline
Ace of the Atmosphere
 
Join Date: Apr 2002
Location: Madison, MS
Posts: 329
skymstr02 is an unknown quantity at this point
Quote:
Originally Posted by JeffAxel View Post
the combustion heater uses 2.25lbs/hr on fuel.
I believe that this should read 2.25 GAL/hr. A similiar heater in other types of aircraft (Cessa 310's, 402's, Piper Seneca, Aztec, Navajo, etc) typically burn just over 2 gallons per hour.

This is the service bulletin that describes the changes to the basic installed heaters:
http://www.kellyaerospace.com/servic...-101_Rev_D.pdf
Reply With Quote
  #3  
Unread 01-02-09, 09:01 PM
JeffAxel JeffAxel is offline
Registered User
 
Join Date: Mar 2007
Location: Portland, Oregon
Posts: 150
JeffAxel is an unknown quantity at this point
Quote:
Originally Posted by skymstr02 View Post
I believe that this should read 2.25 GAL/hr. A similiar heater in other types of aircraft (Cessa 310's, 402's, Piper Seneca, Aztec, Navajo, etc) typically burn just over 2 gallons per hour.

This is the service bulletin that describes the changes to the basic installed heaters:
http://www.kellyaerospace.com/servic...-101_Rev_D.pdf
Just quoting the POH on the 2.25lbs/hr. FWIW, the C&D Associates heater I replaced the Janitrol with burns 1.5gph, max according to its Operating handbook. The heaters in 337's are 25K BTU, the larger planes might have bigger heaters, and higher fuel burn rates.
Reply With Quote
  #4  
Unread 01-03-09, 07:56 AM
skymstr02's Avatar
skymstr02 skymstr02 is offline
Ace of the Atmosphere
 
Join Date: Apr 2002
Location: Madison, MS
Posts: 329
skymstr02 is an unknown quantity at this point
Quote:
Originally Posted by JeffAxel View Post
Just quoting the POH on the 2.25lbs/hr. FWIW, the C&D Associates heater I replaced the Janitrol with burns 1.5gph, max according to its Operating handbook.
That's what I'm saying, it was a typo from Cessna, and it never was corrected. God forbid that Cessna would put out wrong information.
Think about it, 1/3 gph? That is so absurd that this is why a red flag popped up.

Skymaster, Seneca, Seminole, Baron are all comparable sized cabins as far as cubic foot areas, so they all have the same size/family of heaters.
Reply With Quote
  #5  
Unread 12-20-10, 05:33 PM
n86121's Avatar
n86121 n86121 is offline
bigcheese
 
Join Date: Nov 2003
Location: Potomac Airfield~!
Posts: 323
n86121 is on a distinguished road
Question C&D heater remains tepid

I had a C&D put in abut a year ago, and it's outlet air temp remains tepid.

New pump, pressure regulator, etc from C&D

Did you have to do anything special to it?

Did yours eventually put out heat like the old janitrol?

D

Quote:
Originally Posted by JeffAxel View Post
Robert,
the combustion heater uses 2.25lbs/hr on fuel, and draws it from the same tank as the front engine (left). As to the C&D heater, I swapped my old one out at the last annual. The new one actually works, the old one didn't. Be sure whoever does this for you actually reads the installation procedures and follows the checklist and checks that everything is set up properly, and then tests it at altitude. It seems that if the fuel pump for the heater is not up to spec, the heater won't light at altitude. Don't ask how I know! The folks who did this for me hadn't done this before, and didn't do it very well or very efficiently. The total cost was $6800. I won't be going back to this shop. The heater works well though, once it was set up properly.
__________________
David Wartofsky
Potomac Airfield
10300 Glen Way
Fort Washington, MD 20744
Reply With Quote
  #6  
Unread 12-20-10, 09:22 PM
JeffAxel JeffAxel is offline
Registered User
 
Join Date: Mar 2007
Location: Portland, Oregon
Posts: 150
JeffAxel is an unknown quantity at this point
David,
the best suggestion I can make is to call C&D, make an appointment, and fly up and see them in person. They can check the whole thing and get it set up properly. I have heard they are very good at this when you show up on their doorstep and folks leave happy campers. I have no idea as to cost though. FWIW, once my C&D heater was properly set up, it worked just fine. The problem in my case was that the fuel pump didn't put out enough pressure so the heater would light properly. That pump does have a screen that needs cleaning on occasion too.
Reply With Quote
Reply



Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is Off
HTML code is Off
Forum Jump


All times are GMT -4. The time now is 06:52 PM.