Happy Easter Gene! Sounds like you'll have one fine 337.
Regarding charging system upgrades, the paths I'm aware of are fairly limited: 1. Upgrade alternators to 60 amp - PRO: A) No 337 or POH Change required B) 58% increase in power CON: A)Expensive! Labor alone will be $1000+ on top of alternator costs B)Stronger alternator puts additional stress on the rubber coupler, which is a very expensive repair when it fails C) Does not fix the unbalanced nature of the charging system so flashing ALT lights in taxi and cruise may not be resolved. 2. Install Cessna 400 Upgrade - PRO: A)No POH Change required B)Allows alternators to be more efficient by equally balancing the electrical load C) Resolves flashing ALT lights D) Very inexpensive at $499 (by aviation standards at least) E) Installs in 1 hour and any A&P can do it CON: A) Requires 337 field approval 3. R1224 Upgrade - PRO: A) Completely updates charging system and eliminates many older components B)Allows alternators to be more efficient by equally balancing the electrical load C) Resolves flashing ALT lights CON: A) Requires changes to POH B)Ability to re-start alternators in-flight is lost C) Requires field approval and likely a DE D) Costs??? E)Has it ever actually been done??? *Upgrades #1 and #2 may both be installed together |
|
#2
|
||||
|
||||
|
Agree that the -400 series regulator upgrade is “1 wire” simple. Checked today and Cessna 337 is on the R1224 approved model list, so you could also go that direction and install them without field approval or STC as a PMA regulator.
|
|
#3
|
|||
|
|||
|
PM sent Mshac. Thanks!
|
|
#4
|
|||
|
|||
|
Cessna 400 Series Voltage Regulator Upgrade Kit
Hi,
My pressurized Skymaster (FT337GP, F-BXLQ, built in France in 1974) also suffers rear alternator "not charging" blinking lights since I own it (2022). Sometimes even "high volts" red light, and even total panel black out when retracting and extending gear !! I would like to buy your kit and the corresponding installation instructions. Is it possible, as I live in France ? My email adress is : michel.heintz@ue-zenith.eu and phone number is +33 6 70 13 59 72. Thank you for your answer ! |
![]() |
| Thread Tools | |
| Display Modes | Rate This Thread |
|
|