A former member Pete Somers, God rest his soul, was a great contributor to this forum concerning electrical glitches

Tom, you may find some very interesting dialog in Pete's posts. I did a search on Over Voltage and there is lots of goods available on this forum. These events are never new to this forum and because we have about 15 years of posts on this forum there is probably an answer somewhere in the old posts. I didn't have time to drill down today on this issue so when you have time here is some info to research and learn

http://www.337skymaster.com/messages...archid=1327591
__________________
Herb R Harney
1968 337C

Flying the same Skymaster for 47 years
Reply With Quote
  #2  
Unread 11-14-17, 12:13 PM
tomcomet's Avatar
tomcomet tomcomet is offline
Registered User
 
Join Date: Sep 2017
Location: Ontario Canada
Posts: 66
tomcomet is on a distinguished road
Quote:
Originally Posted by hharney View Post
A former member Pete Somers, God rest his soul, was a great contributor to this forum concerning electrical glitches

Tom, you may find some very interesting dialog in Pete's posts. I did a search on Over Voltage and there is lots of goods available on this forum. These events are never new to this forum and because we have about 15 years of posts on this forum there is probably an answer somewhere in the old posts. I didn't have time to drill down today on this issue so when you have time here is some info to research and learn

http://www.337skymaster.com/messages...archid=1327591
Thanks for this Herb. I will do some digging as I hope to avoid this predicament in the future.

TC
__________________
TC
1977 Reims Built F337G
CYFD
Reply With Quote
  #3  
Unread 11-22-17, 02:49 PM
B2C2 B2C2 is offline
Registered User
 
Join Date: Apr 2011
Location: KLVK
Posts: 114
B2C2 is on a distinguished road
It has been pointed out in several posts but bears repeating that the system voltage will get unstable if you have more than the nominal resistance in the field circuit to the alternators. I have also several times had this issue. The first time all crimps were replaced behind the panel in the circuit feeding the field circuit for the alternators. The second time it was fixed by replacing the regulator selector switch. In my 1969 T337D this switch feeds either Reg 1 or Reg 2. Both regulators were showing jumpy voltages. Occasionally lighting the red overvoltage indicator. Replacing the regulator switch caused the voltage to be rock solid. After this was done I disassembled the switch and sure enough the terminals inside were badly worn. I would guess you had an overvoltage condition causing the alternators to go offline. then on recycling everything you got the circuit back. If you have a voltage indicator in your plane look at this. If its jumpy you probably have a field circuit issue.
Reply With Quote
  #4  
Unread 11-22-17, 06:07 PM
hharney's Avatar
hharney hharney is offline
Forum Administrator
 
Join Date: Jul 2002
Location: Michigan (8D4)
Posts: 2,255
hharney is on a distinguished road
Quote:
Originally Posted by B2C2 View Post
In my 1969 T337D this switch feeds either Reg 1 or Reg 2. Both regulators were showing jumpy voltages. Occasionally lighting the red overvoltage indicator. Replacing the regulator switch caused the voltage to be rock solid.
1973 G models and on, DO NOT have the regulator switch. Just so you are not confused the front / rear regulators are automatic in the G and H model Skymasters system. The older system is different and uses a pilot selectable regulator switch.
__________________
Herb R Harney
1968 337C

Flying the same Skymaster for 47 years
Reply With Quote
  #5  
Unread 11-23-17, 05:00 PM
edasmus edasmus is offline
Registered User
 
Join Date: Nov 2006
Location: ARR - Aurora, IL - USA
Posts: 420
edasmus is on a distinguished road
Send a message via AIM to edasmus
Thanks Herb...., you just answered my question!
Reply With Quote
  #6  
Unread 12-08-17, 03:00 PM
B2C2 B2C2 is offline
Registered User
 
Join Date: Apr 2011
Location: KLVK
Posts: 114
B2C2 is on a distinguished road
I looked at the schematic for this system and it looks to me like both regulators are normally active, with the alternator generating the greater output actually acting as the charging alternator due to the diodes in series with the alternator outputs. At similar output voltages both would be active. This is nice as it would cause no issue with a regulator failure, but would limit you to one alternator in that situation. With the older design one regulator feeds both alternators, so if one regulator fails the regulator switch brings both alternators back on line. The design in the G and H models does make it so that if one of the alternators is spiking it will take down the system, and the regulators will still have the path resistance sensitivity, with the alternator field switch as a possible source of higher path resistance similar to the regulator switch in the older system. If you continue to have problems I would say a look at all the connections along the field circuit path starting at the buss bar is worthwhile to see if you have a source of high resistance.
Reply With Quote
Reply



Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is Off
HTML code is Off
Forum Jump


All times are GMT -4. The time now is 04:31 PM.


Powered by vBulletin® Version 3.6.9
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.