Post Read your POH

Directly from the POH:

"The ALT NOT CHARGING lights will normally stay out during idling and taxi operations. Occasionally a light may come on when electrical loads are at a minimum and one engine is operating at a much lower RPM than the other. If one light constantly comes on during idle or taxi with equal engine RPM, or during cruise, the voltage differential between the voltage regulators is too great and the regulators should be adjusted."

One of the last steps in my 400-Series voltage regulator upgrade installation is to adjust the new regulators to the same voltage output at 1600 rpm with a load on the electrical system. This, along with the new paralleling circuit, prevents the lights from coming on at any time unless there is truly a fault in the system.

Also, the trigger voltages for the high output and low output warning lights are fully adjustable. If all you have is the OEM amp gauge, get a cigar lighter digital voltage gauge so you can watch the actual voltage in real time. Here's one at Amazon that displays up to 30 volts and provides two USB power outlets: https://smile.amazon.com/dp/B01N00I4...XBN6VJS7V3F5P1 If you don't like that one, there are many other styles available.

Last edited by mshac : 12-09-21 at 06:25 PM.
Reply With Quote
  #2  
Unread 04-20-25, 02:15 PM
GeneCopeland GeneCopeland is offline
Registered User
 
Join Date: Aug 2018
Location: Texas
Posts: 5
GeneCopeland is on a distinguished road
Need to purchase 400 conversion paper n parts?

Hello,
Working on my ‘75 T337G. Currently undergoing 2nd avionics upgrade, removing G5s and stock engine indicating, replacing with GI275s (5 of them) and new panels that should clean it up quite a bit. Moving CBs to new instrument panel and eliminate CB panel at my knee.
Was thinking about installing the Peter Schiff AC system as they said they had done one, presumably yours? Anyhow, I started looking into an alternator upgrade and saw the options for R1224 or the Cessna 400 regulator thread.
Very much interested in this as my alternator lights flicker during taxi/ low power AND eliminating the extra circuits, diode, field excite, etc
Also looking for possible plug and play alternators rated at more than my 38amps?
Any and all input is welcomed, interior is next, planning, vacuum formed kydex for window surround and ceiling panels as mine are so brittle,

Gene Copeland
972-757-7120
Based KGPM,
N662KC P3370216
Reply With Quote
  #3  
Unread 04-20-25, 03:44 PM
mshac's Avatar
mshac mshac is offline
Registered User
 
Join Date: Aug 2020
Location: North Texas
Posts: 766
mshac is on a distinguished road
Happy Easter Gene! Sounds like you'll have one fine 337.

Regarding charging system upgrades, the paths I'm aware of are fairly limited:

1. Upgrade alternators to 60 amp -
PRO: A) No 337 or POH Change required B) 58% increase in power
CON: A)Expensive! Labor alone will be $1000+ on top of alternator costs B)Stronger alternator puts additional stress on the rubber coupler, which is a very expensive repair when it fails C) Does not fix the unbalanced nature of the charging system so flashing ALT lights in taxi and cruise may not be resolved.

2. Install Cessna 400 Upgrade -
PRO: A)No POH Change required B)Allows alternators to be more efficient by equally balancing the electrical load C) Resolves flashing ALT lights D) Very inexpensive at $499 (by aviation standards at least) E) Installs in 1 hour and any A&P can do it
CON: A) Requires 337 field approval

3. R1224 Upgrade -
PRO: A) Completely updates charging system and eliminates many older components B)Allows alternators to be more efficient by equally balancing the electrical load C) Resolves flashing ALT lights
CON: A) Requires changes to POH B)Ability to re-start alternators in-flight is lost C) Requires field approval and likely a DE D) Costs??? E)Has it ever actually been done???

*Upgrades #1 and #2 may both be installed together
Reply With Quote
  #4  
Unread 04-21-25, 06:31 PM
Learjetter's Avatar
Learjetter Learjetter is offline
Registered User
 
Join Date: Jun 2010
Location: KOKC
Posts: 274
Learjetter is on a distinguished road
Agree that the -400 series regulator upgrade is “1 wire” simple. Checked today and Cessna 337 is on the R1224 approved model list, so you could also go that direction and install them without field approval or STC as a PMA regulator.
Reply With Quote
Reply



Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is Off
HTML code is Off
Forum Jump


All times are GMT -4. The time now is 12:54 PM.


Powered by vBulletin® Version 3.6.9
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.